Coldplate Manifold·Halcyon Compute

Trial 1

FailureA413Feb 19, 2026

Goal

Fill the full channel network and pressure test at 2.5 bar.

Process

Pour temp
690C
Mold temp
200C
Alloy batch
A413-2602-A
Trial date
Feb 19, 2026
Gating
Two gates at opposite corners, vents at each channel end.
Changed from the previous trial
First trial on this tool

What came out

Defects observed

Leak at the third channel junction on all six parts. Misrun at two channel ends.

Lessons learned

Two corner gates fight each other in the middle. The front stalls where they meet.

Trial sequence

3