Coldplate Manifold·Halcyon Compute

Trial 3

SuccessA413Mar 24, 2026graduated to production

Goal

Open the far corner vent and hold 2.5 bar across the batch.

Process

Pour temp
695C
Mold temp
205C
Alloy batch
A413-2603-C
Trial date
Mar 24, 2026
Gating
Single end gate, one 6mm vent plus three 3mm.
Changed from the previous trial
Far corner vent 3mm to 6mm.

What came out

Defects observed

Six of six held 2.5 bar for ten minutes. No visible porosity on section.

Lessons learned

Vent the last place to fill, and vent it bigger than feels necessary.

Trial sequence

3