Pump Volute
ProductionA413ComplexAt riskpump-volute
Where this job stands
Spiral core. Four trials to get the gating right, then it has run clean.
Commercial
- Tooling cost
- $5,981
- Committed volume
- 1,000 pcs
- Quote
- Q-2603-VANT-01Geometry
- Quoted per piece
- $19.75
- Break-even against CNC
- 29 pcs
- Rework buffer
- Included in quote
Geometry
- Solid volume
- 231,800 mm3
- Intersection volume
- 318,200 mm3
- Bounding box
- 142 x 138 x 82 mm
- Casting weight
- 0.846 kg
- Parts per mold
- 4recomputed 4
- STEP file
- uploads/vantage/pump-volute-r5.step
Casting trials
4Production runs
295.1% yield
| Date | Ordered | Delivered | Yield | $/pc | Margin | Batch |
|---|---|---|---|---|---|---|
| Jun 25 | 400 | 372 | 93.0% | $22.51 | 21.7% | A413-2606-D |
| Aug 6 | 600 | 579 | 96.5% | $21.13 | 25.3% | A413-2608-C |
Rework
216.5 hrs
| Logged | Trigger | Status | What happened | Hrs |
|---|---|---|---|---|
| Aug 9 | Dimensional | Partial | Twenty one parts with the inner spiral wall 0.4mm thin on one side. Fix: Core print shimmed. Investigating whether the print is wearing. Run of Aug 6 | 7.5 |
| Jun 27 | Porosity | Resolved | Twenty eight parts with porosity at the outer wall gate witness. Fix: Scrapped. Gate contact ground back and blended before the next shot. Run of Jun 25 | 9.0 |
Porosity observations
2| Logged | Where | Severity | Cause | Fix | Resolved |
|---|---|---|---|---|---|
| Aug 8 | Volute throat, inner radius | Minor | Gating | Open | |
| Jun 26 | Outer wall at the gate witness | Moderate | Gating | Gate contact ground back and blended. | Yes |
Knowledge from this job
2Job opened Mar 22, 2026 · 4 trials · 2 runs · 951 pieces delivered